6. COMMISSIONING AND ADDITIONAL INSTRUCTIONS
77
The insulation checks of the mains cable
1) Disconnect the mains cable from the terminals L1, L2, and L3 and from mains.
2) Measure the insulation resistance of the mains cable between phase conductors 1 and 2, between phase conductors 1
and 3, and between phase conductors 2 and 3.
3) Measure the insulation resistance between each phase conductor and the earth conductor.
4) The insulation resistance must be
>
1 MΩ at the ambient temperature of 20 °C (68 °F).
The insulation checks of the motor
1) Disconnect the motor cable from the motor.
2) Open the bridging connections in the motor connection box.
3) Measure the insulation resistance of each motor winding. The voltage must be the same or higher than the motor nominal
voltage, but not higher than 1000 V.
4) The insulation resistance must be
>
1 MΩ at the ambient temperature of 20 °C (68 °F).
5) Obey the instructions of the motor manufacturer.
6.5 INSTALLATION IN AN IT SYSTEM
If your mains is impedance-grounded (IT), the AC drive must have the EMC protection level C4. If your drive has the EMC pro-
tection level C2, it is necessary to change it to C4. To do this, remove the EMC jumpers.
WARNING!
Do not make changes in the AC drive when it is connected to mains. The components of the drive are live when
the drive is connected to mains.
CAUTION!
Before you connect the AC drive to mains, make sure that the EMC level of the drive is correct. An incorrect EMC
level can cause damage to the drive.
6.5.1 FRAMES MR4, MR5, AND MR6
Change the EMC protection of the AC drive to level C4.
1) Open the cover of the AC drive.
2) In MR4 and MR5, to find the EMC jumpers, remove the cable cover.
N800A
Summary of Contents for N800 Series
Page 2: ...ISSUEDATE 2015 06 26 VER 1 ...
Page 3: ......
Page 19: ...3 MOUNTING 3 2 2 WALL MOUNTING OF MR5 Fig 3 ThedimensionsoftheACdrive MR5 13 N800A ...
Page 20: ...3 MOUNTING 3 2 3 WALL MOUNTING OF MR6 Fig 4 ThedimensionsoftheACdrive MR6 14 N800A ...
Page 21: ...3 MOUNTING 3 2 4 WALL MOUNTING OF MR7 Fig 5 ThedimensionsoftheACdrive MR7 15 N800A ...
Page 23: ...3 MOUNTING 3 2 6 WALL MOUNTING OF MR8 IP00 Fig 7 ThedimensionsoftheACdrive MR8 IP00 17 N800A ...
Page 52: ...4 POWERCABLING 46 3 Removethecablecover MR8 MR9 N800A ...
Page 53: ...4 POWERCABLING 47 4 Removethecableentryplate MR8 MR9 N800A ...
Page 54: ...4 POWERCABLING 48 5 MR9only Loosenthescrewsandremovethesealingplate N800A ...
Page 55: ...4 POWERCABLING 49 6 RemovetheEMCshieldplate A ThewingnutinMR8 A MR9 N800A ...
Page 80: ...5 CONTROLUNIT 74 Fig 30 Thegalvanicisolationbarriers A Thecontrolunit B Thepowerunit N800A ...
Page 101: ......