6-15
HYDRAULIC OIL
Using dipstick, measure oil level, and oil if
necessary.
When changing hydraulic oil, clean
suction strainer(screwed into outlet port
pipe) and line filter(screwed into inlet
pipe). Line filter uses paper element, so
replace periodically(every 6 months or
1200 hours)
GROUP 2 OPERATIONAL CHECKS AND TROUBLESHOOTING
1. OPERATIONAL CHECKS
CHECK ITEM
Check visually for deformation, cracks or
damage of rod.
Load maximum load, set mast vertical and
raise 1m from ground. Wait for 10
minutes and measure hydraulic
drift(amount forks move down and amount
mast tilts forward).
·
Hydraulic drift
- Down(Downward movement of forks)
: Within 100mm(3.9in)
- Forward(Extension of tilt cylinder)
: Within 5
。
If the hydraulic drift is more than the
specified value, replace the control valve
or cylinder packing.
Check that clearance between tilt cylinder
bushing and mounting pin is within
standard range.
(1)
(2)
(3)
1)
2)
Within 100mm(3.9in)
(after 10min)
Within 5
(after 10min)
Standard
Under 0.6 (0.02)
mm (in)
(1)
(2)
Dipstick
Filter
Drain plug
Hot
Normal
Cold
CONTROL VALVE
Raise forks to maximum height and
measure oil pressure.
Check that oil pressure is 188kgf/cm
2
.
(2675psi)
60L7AHS11
60L7AHS12
60L7AHS18
3)
(1)
Summary of Contents for 60L-7A
Page 32: ...2 7 Mast Refer to section on mast Page 2 2 1 2 POWER TRAIN ASSEMBLY REMOVAL 1 D503RE04 ...
Page 69: ...3 28 50DFTM13 Remove bearing 67 and gear 68 30 68 67 ...
Page 71: ...3 30 Remove oil seal 72 from the transmission case 34 50DFTM17 72 ...
Page 188: ...7 3 10MM RING ELECTRIC CIRCUIT FOR LPG FUE KIT 35L7AEL07 ...
Page 189: ...7 4 MEMORANDUM ...