![HYOSUNG KARION RT125 Service Manual Download Page 108](http://html1.mh-extra.com/html/hyosung/karion-rt125/karion-rt125_service-manual_2193065108.webp)
Insert the caps firmly
Separation of electrolyte container.
After confirming that the electrolyte has entered the bat-
tery completely, remove the electrolyte containers from
the battery.
Insert of the caps
Insert the cap into the filler holes, pressing in firmly so
that the top of the caps do not protrude above the upper
surface of the battery s top cover.
SERVICING
Visually inspect the surface of the battery container. If
any signs of cracking or electrolyte leakage from the
sides of the battery have occurred, replace the battery
with a new one. If the battery terminals are found to be
coated with rust or an acidic white powdery substance,
then this can be cleaned away with sandpaper.
RECHARGING OPERATION
Using the pocket tester, check the battery voltage. If
the voltage reading is less than the 12.8V (DC),
recharge the battery with a battery charger.
Voltage
Less than 11.5V
Between 11.5~12.8V
More than 12.8V
Charge 20Hour as 0.7A
Charge 5~10Hour as 0.7A
No charge
How to charge
CAUTION
Draw out slowly otherwise in case of remain elec-
trolyte vaporize.
5-15
ELECTRICAL SYSTEM
After recharging, wait for more than 30 minutes and
check the battery voltage with a pocket tester.
If the battery voltage is less than the 12.8V, recharge
the battery again.
If battery voltage is still less than 12.8V, after
recharging, replace the battery with a new one.
When the motorcycle is not used for a long period,
check the battery every 1 month to prevent the bat-
tery discharge.
CAUTION
When recharging the battery, remove the battery
from the motorcycle.
NOTE
Do not remove the caps on the battery top while
recharging.
CAUTION
Be careful not to permit the charging current to
exceed 3A at any time.