Page 42
Two-fold sealing of the electrodes for the steam cylinder
CY45/2 (SLE50/65)
»
Hand tighten the nuts.
»
Reassemble the cylinder and insert
it into the unit (see chapter
Reinstal-
lation of the steam cylinder
).
»
Follow the instructions in the section
Leak test
.
Genuine electrode length
HygroMatik large area electrodes made from
stainless steel have the following genuine
lengths:
*)
The electrodes installed in the new CY45/2
steam cylinder feature a length of 300 mm
Electrode wear
Eelctrode wear depends on:
•
composition and conductivity of the
supply water
•
the amount of steam produced
In case of the electrodes being burned-off to
less than one third to half of their genuine
length, electrode replacement should be
made.
When cylinder water maximum level is
detected for a period of 60 mins, an error
message (s. FlexLine control manual, „Faults
and warnings“ section) is generated and unit
operation is cut. At the latest, electrode
replacement should then be made.
Model
Lenght [mm]
Kit E02 / SLE 02
80
Kit E06 400 V/3 Ph
125
Kit E06 220-240 V/1 Ph
Kit E10 / SLE 05/10
155
Kit E15/30 / SLE15
235
Kit E20 / SLE20
210
Kit E45/65 / SLE45/65
300
Kit E02 / SLE 02
80
Kit E02 / SLE 02
80
O-ring
hidden
O-ring
electrode