Page 9
3. Overview of the operation
and layout of a steam bath
The HygroMatik steam generator provides
the steam bath with the steam required for
operation. The temperature measured in the
steam bath is the only control variable used
to control the steam production. When stan-
dard settings are used, the steam bath
reaches approx. 45 °C at 100% humidity.
One or, if required, two supply fans introduce
fresh air to the steam bath, one or two
exhaust fans extract warm air from the steam
bath to ensure a continuous supply of steam
and stable temperature control. The steam
generator can control up to 4 essence injec-
tors.
Heating-up phase:
Steam is supplied to the steam bath, which is
still cold. As a result, the relative humidity
increases first to 100%, while the tempera-
ture remains almost constant. A further sup-
ply of steam then increases the temperature;
the relative humidity remains at 100%.
Operational phase:
When the set point temperature value +
switch-off temperature difference has been
reached, steam production is interrupted. If
the steam bath temperature sinks below the
adjustable set point temperature, steam is
again introduced into the cabin.
Controls for lights, fans and essences are
optional accessories. The HygroMatik steam
bath functions are optionally available in 24 V
or 230 V versions.
There is a danger of electric shock due in
case of non-observance!
Only safety extra-low voltage (24 V) may be
used in the steam cabin for fans and lights.
3OHDVHQRWH
:$51,1*