No. Parameter
No.
Meaning/comment
[ ] explains the term in the glossary
min
max
FP
[ ] refers to a related term explanation
3 Temp._actual_value
The actual value [1] of the steam bath temperature
4 Temp._set_value
20.0
49.0
45.0
The set value [3] of the steam bath temperature
7 Steam_actual_unit
The current steam output [4] in kg/h
9 Steam_output_max.
The set value of the maximum steam output [43] as a percentage of the nominal output [99]
10 Demand
The current demand [5] as a percentage of the maximum level
11 Control_sig._internal
The internal actuator signal [42] controls the power element [100] of the unit
12 Output_signal
The output signal [69] can be used to control additional units
13 Current_actual_cyl. 1
The current amperage (only for ELDB [77])
14 Current_actual_cyl. 2
The current amperage (only for ELDB [77] double cylinder units)
15 Water_level_cyl. 1
The water level in level control in mm (only for HKDB [78])
16 Water_level_cyl. 2
The water level in level control in mm (only for HKDN [78] double cylinder units)
19 Essences_selection
The selected essence pump from No. 1 to No. 4
Adjustment/value range
Reading value
Reading value
Reading value
Reading value
Reading value
Reading value
Factory presets (FP) bold
Reading value
Reading value
Reading value
Reading value
Reading value
Table of the reading values available in the main display and the set value of the steam bath