4-15: Machine Maintenance
Adjustment
1. If the pump continues to run for longer than 3 to 5 seconds, turn the screw
counterclockwise
until the pump switches off (see Figure 4-5).
2.
If the pump switches off as soon as the hose is disconnected (less than 3 to 5
seconds), turn the pump screw clockwise one complete turn.
3. With the pump still on, reconnect the solution hose onto the Flex unit (see
The pump should switch on.
4.
Repeat steps 1 through 3 on this page until the pump switches off within 3 to 5
seconds after the hose is disconnected.
CLOCKWISE
CLOCKWISE
COUNTERCLOCKWISE
COUNTERCLOCKWISE
Figure 4-5. Insert Hex L-Key and Turn It Counterclockwise/Clockwise