Error messages / troubleshooting
FAM 15-70 ATEX
en
Page 51 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
[H10] Change fluid filter
S
te
p
Description
Malfunction:
"Replace fluid filter"
1.
Press the RESET button to acknowledge/reset the fault.
2.
Switch off the unit at the main switch.
3.
Close the ball valves on the inlet IN and outlet OUT.
4.
Empty the filter housing via the drain ball valve.
5.
Replace the filter element according to the description on page
66.
6.
Open the ball valves on the inlet IN and outletOUT.
7.
Switch on the unit at the main switch.
8
Does the error re-
occur ≈ 5 minutes?
9.
-> a. Yes
-> proceed to Step 10.
-> b. No
-> proceed to Step 11.
10.
Check the differential pressure switch and the feed lines.
11.
The error is repaired.