Performing maintenance / inspection
FAM 15-70 ATEX
en
Page 81 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
Replacing the filter element on the oil mist separator
Quit automatic mode on the FAM. Afterwards, wait
approximately ~1 minute, until normal pressure
(ambient pressure) has been established in the
vacuum column.
Turn the separator pot (2) 1/8th of a turn to the left
(bayonet seal) and remove it from the bottom.
Turn the used filter element clockwise to remove and
dispose of it in an environmentally correct manner.
(The element shown here may vary visually)
Insert the new filter element and turn it in a
counterclockwise direction in the separator head (1).
Insert the separator head (2) into the separator head
(1) and secure it by a 1/8 turn (bayonet seal).
The filter element change is now complete.