Error messages / troubleshooting
FAM 15-70 ATEX
en
Page 47 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
[H6] Entry (IN) blocked
S
te
p
Description
1.
Malfunction:
"Inlet clogged"
2.
Cause: No medium is making it into the vacuum column
3.
Check the setting of the shut-off devices in the suction line. If
they are closed, then open them. Check/clean the suction
strainer.
4.
Press the RESET button to acknowledge/reset the fault.
5.
Does the error re-occur after
≈ 2.5 minutes?
6.
-> a. Yes
-> proceed to Step 7.
-> b. No
-> proceed to Step 8.
7.
Check the following points:
-
Check the suction pipe for cross-section constriction.
-
Check the functioning of the vacuum pump in manual mode.
-
Are all shut-off devices in the suction line open?
8.
The failure is repaired
Summary of Contents for FAM-50-M-2-A-45-Z-Z-D-Z-1/-EX02-F
Page 87: ......