Error messages / troubleshooting
FAM 15-70 ATEX
en
Page 48 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
[H7] Outlet (OUT) blocked
S
te
p
Description
1.
Fault:
"Outlet clogged"
Cause: Medium cannot flow out of the vacuum column
(evacuation pump pressure limit = 5 bar)
2.
Check the position of the shut-off devices in the return line. If
they are closed, then open them. Check/clean the suction
strainer.
3.
Press the RESET button to acknowledge/reset the fault.
4.
Does the error re-occur after
≈ 4 minutes?
5.
-> a. Yes
-> proceed to Step 6.
-> b. No
-> proceed to Step 7.
6.
Check the pressure relief valve of the evacuation pump for
proper functioning.
7.
The failure is repaired.