General Safety Information
FAM 15-70 ATEX
en
Page 13 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
When work is done in explosion-prone areas, the safety of persons
and equipment depends on the observance of all relevant safety regulations.
The installation and maintenance personnel thus carries particular
responsibility. Exact knowledge of the applicable regulations and conditions
is required.
Please note:
Observe the characteristic curves and measurement operating conditions
of the rating plates and data plates.
Damage to the devices can nullify the explosion protection.
The unit may be operated only when the switch cabinet is completely
closed.
Conversions and modifications to the devices and components that affect
the explosion protection are not allowed.
Depending on the version (see model code), use the FAM only in connection
with the following media:
NOTICE
Impermissible operating conditions
The unit will be damaged
►
The unit may be used only in connection with the media mentioned
below.
Depending on the version (see model code), the FAM may only be used for
the following media (see model code):
FAM-xx-
M
-x-x/xxxx-xxx-xx-x-x-x
Mineral oils acc. to DIN 50524
Gear oils acc. to DIN 51517, 51524
Other hydraulic and lubrication oils which
require or are compatible with NBR
seals.
FAM-xx-
B
-x-x/xxxx-xxx-xx-x-x-x
Synthetic esters (HEES) DIN 51524/2
Vegetable oils (HETG, HTG)
Hydraulic and lubrication oils which
require or are compatible with Viton
seals.
Summary of Contents for FAM-50-M-2-A-45-Z-Z-D-Z-1/-EX02-F