Performing maintenance / inspection
FAM 15-70 ATEX
en
Page 78 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
4.
Carry out the corresponding
resistance measurement on
the teA2-X2:1 (5, 6,
7). In order to do this,
remove the single leads
from the terA2-
X2:5;6;7.
5.
Set the multimeter to resistance measurement.
6.
Insert the instrument leads on the multimeter into the bushings for
resistance measurement.
7.
Connect a instrument lead firmly with +A2-X2:1 for example, with a
crocodile clip.
8.
Also connect the second instrument lead with the wire from +A2-X2:5;
6; 7 of the contact to be measured e.g. with a crocodile clip.
9.
Now bring each float into position by it closing the contact.
10. The contact is OK if the measurement unit displays a resistance of
≤
1.2
Ω after a measuring time of around 5 seconds.
If there are larger resistance values, the contact is already damaged
and no longer switches reliably, which leads to sporadic failures.
11. Perform the assembly in reversed order of sequence.