Starting up the unit
FAM 15-70 ATEX
en
Page 42 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
Venting the filter housing
WARNING
Hot fluid
Risk of burns
►
Make sure that hot fluid can exit when
bleeding.
NOTICE
Air in the fluid filter
The filter element is not utilized completely
►
Bleed the fluid filter after each shut-down/filter element replacement
The fluid filter is to be bled through the air-vent
plug (X) in the cover until fluid emerges. Using an
Allen key wrench, carefully open the air-vent plug
(X) in the cover.
It is not necessary to unscrew the air-vent plug
(X) completely
– it contains ventilation slots.