Filling the vacuum pump
Max.
Min.
[a]
[c]
[b]
To fill the vacuum pump, open the fill plug
[a]
. Add oil until the level comes
up to the MAX mark on the sight glass
[b]
.
Check the oil level daily. When the fill level gets down to the MIN mark, add
oil.
The oil fill quantity for the initial filling is ~ 2.0 liters. The oil fill quantity
between the MIN and MAX marks is ~ 0.45 liters.
The vacuum pump is certified for operation with synthetic oil "Leybold LVO
210". If a different oil is used, the EC and ATEX certificates are voided.