Performing maintenance / inspection
FAM 15-70 ATEX
en
Page 66 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
Replacing the filter element on the fluid filter
If the fault indicator lamp "Replace filter element" [H10]" lights up, replace the
filter element on the fluid filter.
See page 66 for details.
To change the filter element, you need the following:
Filter element N15DMxxx (quantity and type dependent on version)
Allen wrench, size 6 mm
Fork wrench, size 13 mm
To change the filter elements, proceed as follows:
1. Switch off the FAM at the main switch and
make sure it cannot be inadvertently switched
back on.
2. Close all shut-off valves at the inlet and outlet.
3. Unscrew the air bleed screw (x) completely
using a 10 mm Allen wrench.