Troubleshooting
SOLUTION
PROBABLE CAUSE
PROBLEM
BMT not energised (Minimum
Tension Coil)
'
Electrical power supply
.
Check: the phases; the
cables; the plug; the socket.
'
BMT Reset switch
.
Make sure that the minimum
tension coil is energised
when switch is turned from 0
to 1. If it is not, replace the
switch.
'
Emergency stop pushbutton
in
.
Make sure the emergency
stop button is released: turn
it clockwise through 1/4 of a
turn to release it.
Electropump is not working
'
Electrical supply
.
Check: phases, cables, plug,
socket and fuse no. 5 in the
electrical plant
'
No--return valve
.
Clean, if blocked replace
'
Filter
.
Clean