5--2
26
Use and maintenance manual
PH211
1 - LED STAND BY
This either confirms machine start up or indicates an emergency state to the
operator.
2 - START BUTTON
During normal operation of the machine, this enables or disables the cutting cycle
start button.
3 - EMERGENCY STOP MUSHROOM BUTTON
Pressing this button immediately stops machine operation. The emergency
button, designed to conform to all safety standards, is positioned so that it is
easily accessible at any time and is clearly visible --- being a red button on a yellow
background. To reset the emergency button, rotate actuator by 45
˚
.
4 - POLARITY CHANGE SWITCH
This selects the blade cutting speed, 40/80 mt/min. on the standard 2---speed
machine.
5 - AUTOMATIC THERMAL- MAGNET CUTOUT WITH MINIMUM
VOLTAGE RELAY AND HATCH LOCKING DEVICE
The machine is provided on the right of the control panel with a main switch with
a locking device which, when set in the ON position (1), powers up the machine
by resetting the minimum---voltage relay and the blade motor thermal magnet
cutout. This device has three protection systems against power failure. When
there is a power failure the electrical devices are all shut down, instantly shutting
down the machine and preventing automatic restoring of power on power return.
A further function is to reset the thermal relay, which protects against overcur-
rents.
6 - MOTOR ENABLING PUSH BUTTON
This push button enables the spindle motor at the band start. It must be pressed
every time the machine is switched on and when the emergency stop button (red
mushroom button) is pressed.
HEAD CONTROL LEVER MICROSWITCH (for manual version only)
The grip of the manual head control lever incorporates a microswitch for manual
control of the blade motor.
Microswitch
Operating
lever
The microswitch is enabled when the machine is not in emergency state. In
compliance with the relevant existing standards, voltage is 24V and the micro-
switch is installed in a housing (blue knob) sealed against external agents such as
dust or moisture, with a protection rating of IP 55.
Summary of Contents for PH 211
Page 1: ...EN YEAR OF MANUFACTURE ______________ PH 211 USE AND MAINTENANCE MANUAL ...
Page 2: ......
Page 6: ......
Page 40: ...6 2 34 Use and maintenance manual PH211 Standardised Wiring Diagrams HB single phase ...
Page 41: ...6 3 35 Diagrams exploded views and replace Standardised Wiring Diagrams three phase ...
Page 44: ...6 6 38 Use and maintenance manual PH211 Motor assembly Handle assembly ...
Page 50: ...6 12 44 Use and maintenance manual PH211 Control panel assembly ...
Page 52: ...6 14 46 Use and maintenance manual PH211 Base assembly ...
Page 54: ...6 16 48 Use and maintenance manual PH211 Vise assembly A Vise assembly B PH 211 ...
Page 56: ...6 18 50 Use and maintenance manual PH211 Stand leg assembly ...
Page 58: ......
Page 72: ......
Page 97: ......
Page 98: ......