45
Part Number make-up
– LX/xxxxxxx/n/xxxxx
LX
/xxxxxxx
/n
/xxxxxx
HWM Logger Type No
Input Channel Configuration
(see tables below)
Shipping
Spec
(See table)
Country code and customer
specific variant option
(See table)
Input Channel Type Matrix (/xxxxxxx)
Channel
Type no
Description
(Note: Add part number characters left to right in the group order shown below)
Power input options
(only to be used if a dedicated connector is required) If required the B must be the first letter.
B
External battery pack connection
Note: Items marked * refer to the input type immediately preceding them, e.g. BG selects a glanded power connection
(Everything before the G/Y will be
glanded into the same cable)
*G
Glanded power cord & 4-pin plug for direct connection to battery pack in lieu of bulkhead connector
(2m)
*Z
Unique cable that will be added as a line item to the SOA
Pressure input
3
External Pressure connector input
– 4 pin bulkhead
6
Internal Pressure transducer (10Bar)
7
Internal Pressure transducer (20Bar)
Note: Items marked * refer to the input type immediately preceding them, e.g. 6N selects 0.1% 10bar transducer
*H
High temperature transducer
*N
High (0.1%) accuracy transducer
Pulse input
(1, A, 4, 8 & 9 all include external battery input, additional external cables may be required)
1
1 channel input (Pulses/Direction) producing 1
“net flow” output channel
A
2 channel inputs (Forward & Reverse pulses) combined to 1
“net flow” output channel (includes
external battery input)
4
1 channel input (Pulses/Direction) producing Forward/Reverse flow logged separately on 2 output
channels (includes external battery input)
8
1 channel input (Pulses) uni-directional pulse input producing 1 output channel (includes external
battery input)
9
1 Status channel input producing 1 output channel
Note: Items marked * refer to the input type immediately preceding them, e.g. 1G selects a glanded 1
channel input (Pulses/Direction) producing “net flow”
(Everything before the G/Y will be glanded into the same cable)
*Y
Glanded ‘Y’ option to connect to external battery pack in lieu of bulkhead connector (2.5m)
*G
Glanded pulse input in lieu of bulkhead connector
Other sensor inputs
2
Voltage 0-10v
5
4-20mA
C
External temperature input
L
Leak Noise Sensor input
M
Modbus
Q
SDI-12
S
Serial channel input for Sonic Sense
SB
Serial channel input for Sonic Sense including External battery pack in 1 connecter
V
Voltage 0-1v
Note: Items marked * refer to the input type immediately preceding them, e.g. MG selects a glanded Modbus connection
*G
Glanded input in lieu of bulkhead connector
GPS Option
X
GPS
Shipping Spec options (/n)
Shipping
Spec no
Description
1
Factory Preset standard.
n
Contact HWM for any specific configuration, depends on order volume
Modem types and data option (/xxxxxx)
Modem
Type no
Description
CCC
xxx
International country letter (determines the modem type)
xxx
nnn
Customer variant code nnn
– For HWM use only.