![Husqvarna F2303P0 Repair Manual Download Page 45](http://html.mh-extra.com/html/husqvarna/f2303p0/f2303p0_repair-manual_172646045.webp)
200889-10
6 FORK, TRIPLE CLAMP
Guideline
0 bar
✓ The vacuum pump is switched off.
- Disconnect the vacuum pump. Remove the special tool.
•
Info
I
The filling port must be positioned at the highest point.
- Mount and tighten the filling screw with the O-ring.
Guideline
Cartridge filling
screw
M4x0.5
2 Nm (1 .5 lbf ft)
e with nitro en
- Clamp the cartridge in a vise using soft jaws.
Info
Clamp the cartridge only lightly.
- Connect the connector of the special tool to the pressure
regulator of the nitrogen bottle.
Filling tool (T14019) (
�
p. 306)
Filling gas - nitrogen
- Adjust the pressure regulator of the nitrogen bottle.
Guideline
I
Gas pressure
11 .2 bar (17 psi)
- Pierce the membrane with the needle of the special tool.
- Open valve
O.
- Fill the cartridge for at least 15 seconds.
Guideline
I
Gas pressure
11 .2 bar (17 psi)
Info
Watch the pressure regulator dial.
Ensure that the cartridge is filled to the specified pres
sure.
- Close the valve.
- Close the nitrogen bottle.
- Remove the special tool.
43