6 FORK, TRIPLE CLAMP
#UM
j
,
-
o
42
Connect adapter
8
to the filling port of vacuum pump G).
I Vacuum pump (T1240S) (
l!,!I
p. 305)
Clamp the control lever as shown in the figure.
✓ Control lever
External tank
(D
is set to
Closed;
Damper
C,
is set to
Vacuum;
and
Oil reservoir
@t is
set to
Vacuum.
Activate
On/Off
switch (3.
✓ The suction process begins.
✓ Pressure gauge @ drops to the required value.
I < 0 bar
✓ Vacuum gauge
@)
drops to the required value.
I 10 mbar
When the vacuum gauge reaches the required value, turn
control lever
Oil reservoir
0
to Equalize pressure.
Guideline
110 mbar
✓ The pressure gauge increases to the required value.
0 bar
When the pressure gauge reaches the required value, turn
control lever
Damper
C,
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the cartridge.
✓ The pressure gauge increases to the required value.
3 bar
When the pressure gauge reaches the required value, turn
control lever
Damper
C,
to Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, acti
vate the
On/Off
switch.