SAFETY INSTRUCTIONS
20 – English
•
To avoid overheating do not use an electric cable
while it is coiled.
•
Always de-energize the machine when carrying out
maintenance work and when it is not in use.
Disconnect the power cable and place it so that it
cannot be connected by mistake.
Personal safety
•
Never use the machine if you are tired, if you have
consumed alcohol, or if you are taking other drugs or
medication that can affect your vision, judgement or
co-ordination.
•
Wear personal protective equipment. See instructions
under the heading ”Personal protective equipment”.
•
Chemicals such as degreasing agent, grease and
hydraulic fluid can give rise to allergies in conjunction
with repeated skin contact. Avoid contact with the
skin, use protective equipment.
•
When in use, the machine can generate dust and
fumes that can contain harmful chemicals. Know the
nature of the material being worked on and wear
appropriate dust mask or respirator protection.
A face mask is especially important when working
indoors due to the limited ventilation. In some
situations it can also be suitable to apply water in
order to decrease the dust.
•
Do not stand on the control cable or the power cable
as there is a risk of your feet becoming tangled.
•
Do not use remote control with cable steering while
working or moving where there is a risk that the
machine can topple. The operator must be
disengaged from the machine.
•
An incorrect maneuver or unforeseeable incident can
result in collapse. Never stand underneath the work
object.
•
Never stand where there is a risk of being crushed.
The machine can rapidly change position. Never
stand underneath a raised arm, even if the machine is
turned off.
•
When the machine is powered, the fan of the radiator
may begin to rotate. Never put your fingers inside the
fan compartment!
•
Reduce the risk when working alone by making sure
that an emergency alarm is available via mobile
phone or other equipment.
•
When moving on a flat surface you must always walk
behind or at the side of the machine. When working or
moving on a sloping surface position yourself above
the machine.
Operation
General
•
Only authorized and trained operators are permitted
to operate the machine and its tools.
•
Never use a defective machine. Carry out inspections,
maintenance and service in accordance with the
instructions in the Operator’s Manual.
•
Rectify any faults or damage that occur immediately.
Prevent the machine from being used before the fault
has been rectified.
•
If the machine becomes unoperable, turn off the
motor before approaching the machine.
•
The machine has been tested and approved solely
with equipment supplied and recommended by the
manufacturer.
•
Under no circumstances should you modify the
original design of the machine without approval from
the manufacturer. Always use original spare parts.
Unauthorized modifications and/or accessories may
lead to serious injury or death to the user or others.
•
Do not modify the machine’s safety devices and check
regularly that they are working properly. The machine
must not be driven if protective plates, protective
covers, safety switches or other protective devices are
not fitted or are defective.
•
Make sure all nuts and bolts are tightened correctly.
•
The machine must be kept clean. Signs and stickers
must be fully legible.
•
Follow the machine’s and the tool’s instructions
carefully when changing tools in order to avoid
injuries.
•
Turn off the electricity supply to the machine before
you take off the remote control or when you leave the
machine to avoid the risk of unintentional operation.
•
Firm handling of the joysticks does not make the
machine stronger or faster. On the contrary, the
joysticks can buckle with unnecessary repairs as a
consequence.
•
Do not lift the remote control by the joysticks.
!
WARNING! This machine produces an
electromagnetic field during operation.
This field may under some
circumstances interfere with active or
passive medical implants. To reduce the
risk of serious or fatal injury, we
recommend persons with medical
implants consult their physician and the
medical implant manufacturer before
operating this machine.
Summary of Contents for DXR-310
Page 75: ...English 75 TECHNICAL DATA Range and transport diagram DXR250 4483 176 5 2020 79 5 4815 189 5 ...
Page 77: ...English 77 TECHNICAL DATA DXR270 4483 176 1986 78 4849 191 1435 56 ...
Page 79: ...English 79 TECHNICAL DATA DXR300 4868 192 2368 93 5231 206 1818 72 ...
Page 81: ...English 81 TECHNICAL DATA DXR310 5182 204 2129 84 2678 105 5549 218 ...
Page 84: ...1158619 27 z Z 78 z Z 78 2016 12 19 US Original instructions ...