40
BALANCING PROCEDURES
The SmartWeight Touch®/GSP9200 Touch Servo-
Activated Laser automatically locates BDC to aid in fast
adhesive weight positioning.
Figure 154.
The BDC laser locator automatically displays a vivid line
at bottom dead center after a wheel has been spun. The
laser turns off when the wheel is spun again.
Use of controls or adjustments or performance
of procedures other than those specified herein
may result in hazardous radiation exposure.
With the servo enabled, attach the adhesive weight using
the weight amount shown for the right weight plane on
the screen.
TruWeight™ shows the operator exactly how to place the
weights on the wheel. Place them exactly as displayed on
the screen.
Close the safety hood to perform a check spin.
Left and right weight plane displays should show “OK”
after check spin.
Figure 155.
MIXED WEIGHTS balancing procedure is complete.
The SmartWeight Touch®/GSP9200 Touch will find the
top-dead-center (TDC) for the first weight plane if “Servo-
Stop” is enabled. “Servo-Stop” will hold the wheel in the
TDC position while the weight is applied.
Figure 151.
Attach the clip-on weight amount shown on the screen for
the left weight plane to the inner rim of the wheel.
TruWeight™ shows the operator exactly how to place the
weights on the wheel. Place them exactly as displayed on
the screen.
If the optional HammerHead
®
TCD weight
locator is installed, the weight should be applied
at the location marked by the laser.
Figure 152.
Touch the green “START” button with the safety hood in
the raised position.
Figure 153.
Optionally, pressing the next plane weight
amount will rotate the wheel to the next weight
plane.