45
a
)
、
Adopt reply mode
b
)
、
Time for each frame transmit should more than 20ms
7
)
、
Register address and function instruction
:
No.
Function
Address
Parameter
Note
Readable/editable data
1
Set current
42000
SLG-200HF
:
35A
~
205A
SLG-300HF
:
55A
~
305A
SLG-400HF
:
55A
~
405A
2
Reservation
42001
/
3
Reservation
42002
/
4
Gas pre flow
42003
0.2s – 5s
Data is times of 0.1s
5
Gas post flow time
42004
5s – 100s
6
Reservation
42005
/
7
Start
42006
1/0
1work
8
Gas check
42007
1/0
1work
9
Reservation
42008-
/
Read and edit reservation
address is illegal
10
Stop
43000
1/0
1work
11
Current up slope time
43001
0.10s – 1.00s
Data is times of 0.01s
12
Manual pump function
43002
1/0
1work
13
Cutting time set
43003
1 – 999min
14
Penetration times set
43004
1 – 999
次
15
Monitoring control switch
43005
1/0
1 work
16
Monitoring alarm
function
43006
1/0
1work
17
Corner
43007
1/0
1work
18
Reservation
43008-
/
Read and edit reservation
address is illegal
Read only date
19
Exact current
45000
As set current
20
Reservation
45001
/
21
Arc strike success
45002
1/0
1 arc strike success
22
Error code
45003
/
23
Reservation
45004-
/
Read and edit reservation
address is illegal
24
Cutting time left
46000
0-999min
25
Penetration times left
46001
0 – 999
26
Coolant temperature
46002
-30 – 71
℃
>128 is -
,
<128 is +
27
Coolant flow
46003
0-10L/min
Data is times of 0.01L/MIN
28
Reservation
46004-
/
Read and edit reservation
address is illegal
Summary of Contents for SLG-200HF
Page 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...
Page 22: ...15 5 2 Installation Drawing System components A Plasma power sourceSLG 200HF 300HF 400HF...
Page 47: ...40 3 Circuit diagram 7 1 SLG 200HF...
Page 48: ...41 7 2 SLG 300HF...
Page 49: ...42 7 3 SLG 400HF...
Page 50: ...43 7 4 QFK E1...