4
Rated open circuit voltage
V
360
370
370
Rated duty cycle
-
100%
(
40
℃)
Efficiency
-
93%
93%
94%
Power factor
-
0.79
0.89
0.91
Rated current adjust range
A
40
~
200
60
~
300
60
~
400
Arc voltage output ratio
-
1
:
1
Arc strike mode
-
Non-contact
Plasma gas
-
Air/O
2
/N
2
Shield gas
-
Air/N
2
Gas pressure
MPa
0.5
~
0.7
Quality cutting thickness
(
C.S.
)
mm
25
32
40
Insulation grade
-
F
Cooling mode
-
Air cooling
Protection grade
-
IP21S
Note:
The cutting thickness data got from our standard parts testing, even it can cut thicker material, but it is suggest
that 80% of the workpiece within the above thickness range. It better to cut from the edge, if really need piercing,
then the piercing thickness must no more than the above thickness
2)Dimension
3-1 SLG-200HF dimension and weight
Summary of Contents for SLG-200HF
Page 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...
Page 22: ...15 5 2 Installation Drawing System components A Plasma power sourceSLG 200HF 300HF 400HF...
Page 47: ...40 3 Circuit diagram 7 1 SLG 200HF...
Page 48: ...41 7 2 SLG 300HF...
Page 49: ...42 7 3 SLG 400HF...
Page 50: ...43 7 4 QFK E1...