11
28)
Arc voltage output fuse holder: Arc voltage output fuse holder of cutting power source;
29)
HF power supply connector: connect plasma arc initiator, control the HF power supply
30)
Arc voltage output plug: the arc voltage of cutting power source output it 1:1,
31)
Solenoid valve control connector: connect plasma arc initiator to control the solenoid valve work
32)
CNC connector: connect with the CNC control signal
33)
Robot connector: connect with the robot control signal
34)
RS485 communication connector
:
connect with the automatic control equipment which have digital communication
signal
35)
Protecting gas output plug: to connect the output gas pipe of protecting gas;
36)
Pilot arc cable plug: to connect the striking arc cables;
37)
Plasma gas output plug: to connect the output gas pipe of plasma gas;
38)
Negative pole cable plug: to connect the negative pole cable;
39)
Work-piece cable plug: it connects the work-piece cable (Work-piece cable is also called the ground cable);
40)
Water coolant liquid inlet connector: to connect the coolant liquid return pipe;
41)
Water coolant liquid outlet connector: to connect the coolant liquid supply pipe
2.Arc initiator panel
1)
The plasma torch connector: the torch cable pass through this plug and connect with the corresponding
connectors in the initiator;
2)
The grounding screw: to connect the grounding cable.
3)
Solenoid valve control connector: connect with the solenoid valve control connector
4)
HF power plug: connect with the power source “HF power”
5)
Pilot arc cable plug: to connect the striking arc cable;
6)
The plasma gas plug: to connect the plasma gas output pipe of the plasma power source;
7)
Coolant liquid supply plug: to connect with the coolant liquid supply pipe of the plasma power source;
8)
Coolant liquid return plug: to connect with the coolant liquid return pipe of the plasma power source;
9)
The negative pole cable plug: to connect the negative pole cable;
10)
The protecting gas plug: to connect the protecting gas output pipe of the plasma power source;
Summary of Contents for SLG-200HF
Page 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...
Page 22: ...15 5 2 Installation Drawing System components A Plasma power sourceSLG 200HF 300HF 400HF...
Page 47: ...40 3 Circuit diagram 7 1 SLG 200HF...
Page 48: ...41 7 2 SLG 300HF...
Page 49: ...42 7 3 SLG 400HF...
Page 50: ...43 7 4 QFK E1...