10
5)
Current display indicator
:
unit “A”
。
6)
Digital meter
:
display current, coolant flow, coolant temperature, error code and secondary menu
7)
Gas pressure indicator
:
Indicator always on
:
gas pressure normal
Indicator on 0.3s then off 0.3s
:
gas pressure shortage
(
<0.2MPa
)
,
machine can;t work
Indicator on 0.1s then off 0.1s
:
the machine have problem for pressure shortage before, but already recover to
normal, machine can work
8)
Coolant level indicator
:
indicator always on, the coolant level normal; Indicator on 0.3s then off 0.3s, the coolant level
not enough, machine can;t work
9)
Coolant flow indicator
:
indicator always on, the coolant flow normal; Indicator on 0.3s then off 0.3s, the coolant flow
not enough, machine can;t work
10)
Starting indicator: it lights on when the cutting is start;
11)
Over-heating indicator:
Indicator off: machine normal
Indicator on 0.3s then off 0.3s, the coolant temperature too high, or the inside parts IGBT over heat, machine
can;t work
Indicator on 0.1s then off 0.1s
:
the machine have problem for pressure shortage before, but already recover to
normal, machine can work
12)
Power abnormal indicator
:
indicator always off, machine normal; Indicator on 0.3s then off 0.3s, machine lack phase
or over voltage or lack voltage, machine can;t work
13)
Current adjusting knot: it adjust the cutting current; under the secondary menu, to adjust the secondary menu
parameter
14)
Gas check indicator
:
turn on the gas check, the indicator on
15)
Gas check knob
:
on/off the gas check function
16)
Power switch
:
SLG-200HF is breaker control on/off, SLG-300HF
、
SLG-400HF is urgent stop knob, press this knob, power
off, turn the knob clockwise, power on
17)
Coolant liquid inlet: Fulfill the coolant liquid;
18)
Coolant liquid outlet: discharge the coolant liquid;
19)
Plasma gas pressure adjust filter
:
Adjust the plasma gas(Air or N
2
) working pressure and filter the water
20)
Shield gas pressure adjust filter
:
Adjust the shield gas(Air or N
2
) working pressure and filter the water
21)
Plasma gas input connector
:
input plasma gas, it can be Air/ N
2
or O
2
according to the cutting requirements. When
input Air/ N
2
, it should through 19 filter, when input O
2
, customer need prepare good quality O
2
gas regulator to
adjust the gas pressure
22)
Shield gas input connector
:
input shield gas, it can be Air or N
2
according to the cutting requirements
23)
Ground connect screw
:
connect ground cable
24)
Three phase input power cable connector
:
connect three phase input power
25)
Control fuse
:
Control the circuit fuse
26)
Solenoid valve power supply fuse
27)
HF control fuse
Summary of Contents for SLG-200HF
Page 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...
Page 22: ...15 5 2 Installation Drawing System components A Plasma power sourceSLG 200HF 300HF 400HF...
Page 47: ...40 3 Circuit diagram 7 1 SLG 200HF...
Page 48: ...41 7 2 SLG 300HF...
Page 49: ...42 7 3 SLG 400HF...
Page 50: ...43 7 4 QFK E1...