NOTE
If the test result shown in
Conclusion
is
AB all break off or no phone connected
, the phone is faulty or
the line between the phone and the MA5612 is not properly connected. In this case, replace the phone or
check whether the line is connected properly.
Step 4
Check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 5
8.3 POTS Subscriber Circuit Line Test
l
If all the test results are normal, the voice board is normal. Then, go to
l
If not all the test results are normal, the voice board is faulty. Then, go to
.
Step 6
Use another port on the same board and check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 7
Replacing the service board and check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 8
Check whether the power board is working properly by referring to the power supply indicator
status on the board. For the status description of the power supply indicators, see
l
If the power board is working properly, go to
l
If the power board is not working properly, go to
Step 9
Replace the power board with anther one. Then, check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 10
Check MA5612 hardware and the ambient environment.
1.
Ensure that the device is grounded according to requirements. For details, see
. Check whether the fault is rectified.
l
If the fault is rectified, go to
.
l
.
2.
Check whether the control board is inserted properly.
l
If the control board is inserted properly, go to
.
l
If the control board is not inserted properly, insert it properly. Then, go to
.
3.
Take the phone off the hook to check whether the fault is rectified.
l
If the fault is rectified, go to
.
l
.
4.
Check whether the MA5612 is operating properly.
Check for leaks in the roof of the cabinet, water trails on the chassis, dust in the interior of
the chassis, and evidence of vermin. Also check whether the chassis is properly sealed.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
5 Troubleshooting Services Transmitted Through a GPON
Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
169