l
If the board is firmly inserted, go to
l
If the board is not firmly inserted, remove and insert the board, and ensure that the board
is firmly inserted. Then, go to
NOTE
If the board is not properly installed, component detection fails during board startup and therefore the
startup fails. The fault can be rectified only by removing and inserting the board.
Step 7
Check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 8
Replace the original board, wait for about five minutes, and then check whether the new board
is in the normal state.
NOTE
A board is in the Auto_find state after being discovered automatically. After the board confirm
frameid/slotid
command is executed to confirm the board status, the board is in the normal state.
l
If the new board is in the normal state, the original board is faulty. Go to
l
If the fault persists, go to
.
Step 9
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 10
End.
----End
6.5 A Service Board Fails to Register
This topic describes how to troubleshoot a fault when a service board of an MA5612 fails to
register.
Location Method
Use the following guidelines to locate the fault:
1.
Check whether the board is properly installed.
2.
Check whether the board is faulty.
CAUTION
l
To facilitate fault report, save the results of the following steps.
l
Take ESD measures before removing and inserting a board.
Procedure
Step 1
Check whether the board is properly installed.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
6 System Fault Handling
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.