l
If the test result (shown in
Conclusion
) is not
Normal
, rectify the fault based on the test
.
NOTE
If the test result shown in
Conclusion
is
Phone not connected
, the phone is faulty or the line between the
phone and the MA5612 is not properly connected. In this case, replace the phone or check whether the
line is connected properly.
Step 8
Pick the phone off the hook again and check whether a dial tone is heard.
l
If a dial tone is heard, go to
.
l
If no dial tone is heard, proceed to
.
Step 9
On the MGC, query subscriber data and check whether data of the subscriber who encounters
the fault is configured on the MGC.
l
If data of the subscriber who encounters the fault is configured on the MGC, go to
.
l
If data of the subscriber who encounters the fault is not configured on the MGC, configure
such data on the MGC. Then, proceed to
Step 10
Pick the phone off the hook again and check whether a dial tone is heard.
l
If a dial tone is heard, go to
.
l
If no dial tone is heard, proceed to
Step 11
On the MGC, trace H.248 signaling, and check whether error 502 is contained in H.248 signaling.
l
If error 502 is contained in H.248 signaling, run the
tid-template modify
command to
modify the terminal ID format of the MG to be the same as that of the MGC. In the H.248
mode, run the
reset coldstart
command to reset the MG interface and make the subscriber
register again. Then, go to
.
l
If error 502 is not contained in H.248 signaling, go to
NOTE
In the protocol, error 502 is defined as invalid termination point, including RTP termination point and
physical termination point. On the MGC, if the traced H.248 signaling contains error 502, it indicates that
the terminal ID format of the MG is different from that of the MGC. For example, RTP configured on the
MGC is in a progressively increase format of RTP1000, RTP1001 and RTP1002; however, RTP configured
on the MG is in a progressively increase format of RTP500, RTP501 and RTP502.
Step 12
In the SIP mode, run the
reset
command to reset the SIP interface and make the subscriber
register again. If registration is successful, run the
display pstn state
command in the global
config mode to check whether the service management state (
CTPAdmState
) of the POTS port
is
StartSvc
.
CAUTION
In resetting the MG interface, subscriber services carried on this interface will be interrupted.
Therefore, before resetting the MG interface, ensure that no users under this interface are running
services.
l
If
CTPAdmState
is
StartSvc
, go to
.
l
If
CTPAdmState
is not
StartSvc
, proceed to
.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
4 Troubleshooting Services Transmitted Through a GE Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.