NOTE
The device displays the following information in the output of the
display log all
command.
---------------------------------------------------------------------------
No. UserName Domain IP-
Address
343 root --
192.168.0.10
Time: 2011-07-11 00:00:02
+08:00
Cmd: reboot
system
---------------------------------------------------------------------------
If the time when the system is unexpectedly reset is the same as the time when the system reset log is
recorded, the user has issued a command to reset the system.
Step 2
Check whether the power supply for the device is normal.
1.
Check whether the power supply for the device has been cut off.
l
If the power supply for the device has been cut off, the system reset is caused by the
power cutoff. Go to
.
l
If the power supply for the device has always been normal, go to
.
2.
Check whether the voltage of the device is normal.
l
If the voltage of the device is normal, go to
.
l
If the voltage of the device is too low, the device may be reset. Go to
NOTE
The working voltage range of the system is as follows:
l
AC power supply: 90 V to 264 V
l
DC power supply: -38.4 V to -72 V
Step 3
Check whether the device temperature is too high.
l
If the device temperature is too high, the system will be automatically reset to protect system
components form being burnt out. Go to
.
l
If the device temperature is within the range, go to
.
NOTE
The working temperatures of the system range from -40°C to +65°C.
Step 4
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 5
End.
----End