2.
Check whether the type of the inserted service board is the same as that configured in the
system.
3.
Check whether the power supply for the service board is normal.
4.
Check whether the service board is inserted properly.
5.
Check whether the board is faulty.
CAUTION
l
To facilitate fault report, save the results of the following steps.
l
Take ESD measures before removing and inserting a board.
Procedure
Step 1
Check whether the service board is added offline.
l
If the board is added offline and is not inserted actually, no need to proceed.
l
If the board is not added offline, go to
.
Step 2
Run the
display board frameid/slotid
command to query the type of the faulty board, check the
type of the actual board inserted into the slot, and then check whether their types are the same
or compatible.
l
If their types are the same or compatible, go to
l
If their types are different or not compatible, check whether the system configurations are
correct. If it is confirmed that system configurations are correct, insert a board of the correct
type as configured in the system into the slot. Then, go to
l
If their types are different or not compatible, check whether the system configurations are
correct. If it is confirmed that system configurations are incorrect, run the
board delete
frameid/slotid
command to delete the original configurations, after the system displays a
message indicating that the board is automatically found, run the
board confirm frameid/
slotid
command to confirm the board. Then, go to
.
Step 3
Wait for five minutes and then check whether the service board is working properly.
l
If the board is working properly, go to
.
l
If the fault persists, go to
.
Step 4
Run the
display broad-service power-off state
command to check whether the function of
powering off the broadband services is in the
On
state.
l
If the function is in the
On
state, go to
.
l
If the function is not in the
On
state, go to
NOTE
When the function of powering off the broadband services is in the
On
state, the device powered by batteries
automatically cuts off the power supply for the broadband services to extend the narrowband service time.
Step 5
Check whether the MA5612 is currently powered by batteries.
l
If the MA5612 is powered by batteries, go to
l
If the MA5612 is not powered by batteries, go to
Step 6
Check whether the board is firmly inserted.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
6 System Fault Handling
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
233