version: 5.0.3.3
l
If yes, go to
.
l
Step 13
If an SSD device has been installed on the server, check whether the driver has initialized the
NVMe device.
Check whether the NVMe device exists in the
/dev
directory.
l
If yes, go to
.
l
Step 14
if the OS uses the irqbalance service to balance CPU interrupts, restart the service by using
one of the following commands after re-loading the driver module:
l
For RHEL 6 or CentOs 6, run
service irqbalance restart
.
l
For SLES 11, run
service irq_balancer restart
.
l
For SLES 12 or RHEL 7, run
systemctl restart irqbalance.service
.
NOTE
l
For RHEL 6, CentOS 6, and SLES 12, you can add IRQBALANCE_ARGS="--hintpolicy=exact" to
the end of the
/etc/sysconfig/irqbalance
file content to better balance interrupts.
l
To configure the irqbalance service in other OSs, refer to documents related to the OSs.
Check whether errors are reported after running the command for restarting the irqbalance
service.
l
If yes, go to
.
l
If no, no further action is required.
Step 15
Contact Huawei technical support for help. For details, see
----End
5.2.2 Upgrading the ES3000 V5 Driver in Windows
Operation Scenario
You can upgrade the ES3000 V5 driver after a later version is released.
Preparations
Before upgrading the driver, check that:
l
You have downloaded the later driver software to the server, and verified the package
integrity.
l
You have checked the driver version.
Procedure
Step 1
Uninstall the existing driver. For details, see
5.1.2 Uninstalling the Driver in Windows
Step 2
Install the new driver. For details, see
3.6.2 Installing the ES3000 V5 Driver in Windows
.
----End
ES3000 V5 NVMe PCIe SSD
User Guide
5 Maintenance and Upgrade
Issue 07 (2019-03-19)
Copyright © Huawei Technologies Co., Ltd.