Sub_OpCode
Description
F10009h
DDR inspection enablement
EF0009h
Temperature inspection enablement
0D0005h
CE concurrency enablement
0E0005h
Read Retry enablement
180006h
Wear leveling enablement
190006h
Inter-chip RAID enablement
1A0006h
Garbage collection (GC) enablement
The enablement status of each function is returned through CQ Dword0.
Table A-26
CQ-Dword0
Bit
Description
00
Enable Status
:
1
indicates that the function
is enabled.
0
indicates that the function is
disabled.
31:01
Reserved
A.6.1.1.4 Querying the Maximum Available Capacity of the SSD
This command is used to query the maximum available capacity that can be set. This
command uses the PRP1, PRP2, Dword10, and Dword12 fields. Enter reserved value 0 for
other fields that are not involved.
Table A-27
Sub_OpCode
Sub_OpCode
Description
0x050009h
Query the maximum available capacity of
an SSD.
The command returns the information to the host through PRP1 and PRP2. The format of the
returned data is as follows:
ES3000 V5 NVMe PCIe SSD
User Guide
A Supported NVMe Commands
Issue 07 (2019-03-19)
Copyright © Huawei Technologies Co., Ltd.