Use Instance
Step 1
Determine the drive health status. For details, see
6.1.3 Querying Basic Information About
a Device6.1.3 Querying Basic Information About a Device
# Query the basic information about
nvme0
.
[root@localhost tool]# hioadm info -d nvme0
Namespace<1> size: 3200.6GB, 3200631791616Byte
formatted LBA size: 512 Byte
formatted metadata size: 0 Byte
maximum capacity : 3200.6GB
current capacity : 3200.6GB
volatile write cache : Disable
serial number : 0503023HDCN107C80013
model number : HWE32P43032M000N
firmware version : 1010
NVMe version : 1.3
device status : healthy
device status
in the command output indicates the SSD controller health status.
The value
healthy
indicates that the device is healthy.
The value
warning
indicates that an exception occurs on the device. For details, see
Step 2
Determine the SMART status of the drive. For details, see
Information About a Device6.1.3 Querying Basic Information About a Device
# Query the SMART information about
nvme0
.
[root@localhost tool]# hioadm info -d nvme0 -s
critical warning : no warning
composite temperature : 308 degrees Kelvin (35 degrees Celsius)
available spare : 100%
available spare threshold : 10%
percentage used : 0%
data units read : 41908532.1 MB
data units written : 31591917.9 MB
host read commands : 661401547
host write commands : 571198332
controller busy time : 481 mins
power cycles : 414 times
power on hours : 8852 h
unsafe shutdowns : 250 times
media and data integrity errors: 0
number of error information log entries: 0
warning composite temperature time: 0 min
critical composite temperature time: 0 min
data status : OK
Critical Warning
: Critical exceptions occur on the device, and emergency handling is
required.
ES3000 V5 NVMe PCIe SSD
User Guide
5 Maintenance and Upgrade
Issue 07 (2019-03-19)
Copyright © Huawei Technologies Co., Ltd.
91