WenZhou ZhengBang Electronic Equipment Co., Ltd
ZB4050LS Rev 1.1
25
Fig.4-31 Open Switch
2.
Parameters Setting
:
Import the value, package, angle, take-up height, component thickness and speed.
The number of trays and tray offsets are only for the IC tray, and the ribbon feeder doesn’t need to be set.
!
Attention
:
The feeder component values and packages must be consistent with the values and packages of the
corresponding components in the CSV file (Including case letter)
When editing the file for the component location, if the synchronization date is selected to the feeder, the
above date will be synchronized automatically, needn’t edit it again.
3.
Coordinate Correction
:
Click “Coordinate” to pop up the coordinate editing box, click “Position” to locate the system preset
coordinate position, then click “Single Feed” to open the feeder cover, adjust the coordinates to align the center position of the
component, and click “Confirm” to save the coordinates.
Fig.4-32 Coordinate Correction
4.
Visual Registration
:
Turn on the vision switch, select the recognition camera and component type, turn on the reclaim function,
click “analog recognition” to start picking up the component to the camera for identification.
Then adjust the threshold slider to stabilize the shape of the locking component and complete the visual registration of the component.