11. Slide the server into the rack.
12. Connect each power cord to the server.
13. Connect each power cord to the power source.
14. Power up the server .
The installation is complete.
HPE Smart Storage Hybrid Capacitor
The HPE Smart Storage Hybrid Capacitor supports the following devices:
• HPE Smart Array SR controllers
• HPE Smart Array MR controllers
IMPORTANT: NVDIMMs are only supported by the HPE Smart Storage Battery.
The capacitor pack can support up to three devices.
This server supports the HPE Smart Storage Hybrid Capacitor with the 145mm cable.
Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware
requirements to support the capacitor pack.
IMPORTANT: If the system BIOS or controller firmware is older than the minimum recommended firmware versions, the
capacitor pack will only support one device.
The capacitor pack is fully charged after the system boots.
Minimum firmware versions
Product
Minimum firmware version
HPE ProLiant DL380 Gen10 Server system ROM
2.00
HPE Smart Array SR controllers
1.90
HPE Smart Array MR controllers
24.23.0-0041
Installing an energy pack option for HPE Smart Storage
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• T-10 Torx screwdriver
• The components included with the hardware option kit
Hardware options installation
74
Summary of Contents for ProLiant DL380 Gen10
Page 33: ...Component identification 33...
Page 58: ...Operations 58...
Page 124: ...7 Install the rear blank from the option kit Hardware options installation 124...
Page 163: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 163...
Page 165: ...Box 1 Box 2 Cabling 165...
Page 167: ...Cable routing Midplane 4LFF drive option Cabling 167...
Page 173: ...Cabling 173...