Systems Insight Display combined LED descriptions
The combined illumination of the following LEDs indicates a system condition:
• Systems Insight Display LEDs
• System power LED
• Health LED
Systems Insight Display LED
and color
Health LED System power
LED
Status
Processor (amber)
Red
Amber
One or more of the following conditions
might exist:
• Processor in socket X has failed.
• Processor X is not installed in the
socket.
• Processor X is unsupported.
• ROM detects a failed processor during
POST.
Processor (amber)
Amber
Green
Processor in socket X is in a pre-failure
condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot X is in a pre-failure condition.
Over temp (amber)
Amber
Green
The Health Driver has detected a
cautionary temperature level.
Over temp (amber)
Red
Amber
The server has detected a hardware critical
temperature level.
PCI riser (amber)
Red
Green
The PCI riser cage is not seated properly.
Fan (amber)
Amber
Green
One fan has failed or has been removed.
Fan (amber)
Red
Green
Two or more fans have failed or been
removed.
Power supply (amber)
Red
Amber
One or more of the following conditions
might exist:
• Only one power supply is installed and
that power supply is in standby.
• Power supply fault.
• System board fault.
Table Continued
Component identification
16
Summary of Contents for ProLiant DL380 Gen10
Page 33: ...Component identification 33...
Page 58: ...Operations 58...
Page 124: ...7 Install the rear blank from the option kit Hardware options installation 124...
Page 163: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 163...
Page 165: ...Box 1 Box 2 Cabling 165...
Page 167: ...Cable routing Midplane 4LFF drive option Cabling 167...
Page 173: ...Cabling 173...