Cabling
HPE ProLiant Gen10 DL Servers Storage Cabling Guidelines
When installing cables, observe the following:
• All ports are labeled:
◦
System board ports
◦
Controller ports
◦
12G SAS Expander ports
• Most data cables have labels near each connector with destination port information.
• Some data cables are pre-bent. Do not unbend or manipulate the cables.
• Before connecting a cable to a port, lay the cable in place to verify the length of the cable.
• When routing cables from the front to the rear of the server, use the cable channels on either side of the chassis.
Cabling diagrams
Use the following tables to find cabling information and diagrams.
Table 3: SAS/SATA kits
Option kit
Cable part number* From
To
Power cable part
number
Front 2SFF SAS/SATA drive cage (SFF)
Drive backplane
System board
SAS Expander
Controller
869810-001
6
869825-001
6
Front 2SFF SAS/SATA 1U drive cage
(LFF)
Drive backplane
System board
SAS Expander
Controller
869810-001
6
Front 8SFF SAS/SATA drive cages
Drive backplane
System board
SAS Expander
Controller
869825-001
6
Table Continued
Cabling
156
Summary of Contents for ProLiant DL380 Gen10
Page 33: ...Component identification 33...
Page 58: ...Operations 58...
Page 124: ...7 Install the rear blank from the option kit Hardware options installation 124...
Page 163: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 163...
Page 165: ...Box 1 Box 2 Cabling 165...
Page 167: ...Cable routing Midplane 4LFF drive option Cabling 167...