c. Connect the fan signal cables.
8.
9.
Install the chassis into the rack.
10. Connect all peripheral cables to the servers and chassis.
11. Connect each power cord to the chassis.
12. Connect each power cord to the power source.
The installation is complete.
1800 W–2200 W power supply fan option
The higher wattage of the HPE 1800 W–2200 W Flex Slot Platinum Hot-plug Power Supply requires additional cooling to
maintain proper thermal condition in the system. To meet this requirement, install the dual-rotor fan 9–10 assembly
included in the HPE r2x00 Gen10 1800 W–2200 W Redundant Power Supply Unit Enablement Kit (PN 880189-B21).
Installing the 1800 W–2200 W power supply fan assembly
Prerequisites
Before you install this option, make sure that you have a T-10 Torx screwdriver available.
Procedure
1.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the chassis.
3.
Disconnect all peripheral cables from the servers and chassis.
Hardware options installation
82