146 Specifications & Regulatory Statements
—
UL 60950-2000
Electrical Safety
WARNING
—
The product power cords are used as main disconnect devices. To
ensure that the power cords can be disconnected quickly, locate the
product near an easily accessible power outlet.
—
Use only UL/CSA approved power cords, SVT type, rated for a suitable
voltage and current. These power cords have two conductors and a
ground. Failure to use the proper power cord may result in an electric
shock or fire hazard.
—
To avoid a fire hazard, the ac branch service must be properly current-
protected by either a fuse or a circuit breaker. Hewlett-Packard
recommends the use of magnetic-type circuit breakers, which are
capable of handling large inrush currents for short durations (10-12
ms) and are rated adequately for the steady state currents. Also, make
sure all equipment is properly grounded.
Class 1 Laser Safety Statement
A. Certification and Classification Information
This product contains a laser internal to the Small Form Factor (SSF) module for
connection to the fiber communications port.
In the USA, the SSF module is certified as a Class 1 laser product conforming
to the requirements contained in the Department of Health and Human
Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated
by a label on the metallic SSF housing.
Outside the USA, the SSF is certified as a Class 1 laser product conforming to
the requirements contained in IEC 825-1:1993 and EN 60825-1:1994,
including Amendment 11:1996.
The SSF includes the following certifications:
* CSA Certified Component (Canada & US)
* TUV Certified Component (European Union)
The following figure shows the Class 1 information label that appears on the
metal cover of the SSF housing:
Summary of Contents for StorageWorks 7110 - Virtual Array
Page 12: ...12 Contents ...
Page 54: ...54 Product Overview Figure 21 VA 7110 I O Architecture ...
Page 90: ...90 Troubleshooting ...
Page 116: ...116 Servicing Upgrading Figure 45 Removing Installing an Array Controller Filler Panel 1 2 3 ...
Page 129: ...Servicing Upgrading 129 Servicing Upgrading Figure 52 Removing and Installing an LCC 1 2 3 ...
Page 130: ...130 Servicing Upgrading Figure 53 Setting the FC Loop Speed Switch Must be set to 1GB s ...
Page 149: ...Specifications Regulatory Statements 149 Specifications Regulatory Statements ...
Page 151: ...Specifications Regulatory Statements 151 Specifications Regulatory Statements ...
Page 152: ...152 Specifications Regulatory Statements ...
Page 164: ...164 Index ...