Servicing & Upgrading 121
Servici
ng & Upgradi
ng
replaced offline, power-on initialization will not complete if the DIMM
memory in both array controllers does not match.
1
Insert the DIMM (
Figure 48
, 2) evenly into the DIMM slot.
2
Use your thumbs to apply even pressure to the top edge of the DIMM and
push the DIMM firmly into the slot. The DIMM extraction levers (1) will
automatically capture the DIMM.
3
Replace the battery. See
"Installing an Array Controller Battery" on
page 118
.
4
Replace the array controller card. See
"Installing an Array Controller" on
page 110
.
Figure 48
Removing & Installing an Array Controller DIMM
1
2