Zone Administration
241
Web Tools Version 3.1.x/4.1.x User Guide
Table 61: Config Tab Field Descriptions
Field
Description
Zoning Method
This displays the method you have selected to add members
to the Zoning database. Choose the zoning method in the
View menu. Valid options are:
■
Mixed Zoning
■
Port Zoning
■
WWN Zoning
■
AL_PA Zoning
The Zoning method determines the information displayed in
the Member Selection List.
Enabled Config
This field displays the currently enabled configuration.
Name
Select an existing configuration from the drop-down menu to
display or modify.
Create Button
Click to create a new configuration. A dialog displays; enter
the name of the new configuration. All names must be unique
and contain no spaces.
Delete Button
Click to delete the configuration selected in the Name
drop-down menu. Deleting a configuration does not delete
any of the elements contained in that configuration.
Rename Button
Click to rename the configuration selected in the Name
drop-down menu. A dialog displays in which you can edit
the Config name.
Member Selection
List
Select available items from the Member Selection list.
Config Members
Displays the current config members.
Add Member
Button
Click to add a member from the Member Selection list to the
Config Members list. You must select a member within the
Member Selection List for this button to become active.
Remove Member
Button
Click to remove a member from the Config Members list. You
must select a member within the Config Members list for this
button to become active.
Summary of Contents for StorageWorks 2/32 - SAN Switch
Page 22: ...About this Guide 22 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 44: ...Installation 44 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 186: ...Fabric Watch 186 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 248: ...Zone Administration 248 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 270: ...Troubleshooting Web Tools 270 Web Tools Version 3 1 x 4 1 x User Guide ...