Zone Administration
215
Web Tools Version 3.1.x/4.1.x User Guide
Disabling Zoning
When you disable the active configuration, the Zoning feature is disabled on the
fabric and all devices within the fabric can communicate with all other devices.
This does not mean that the Zoning database is deleted however, only that there is
no Configuration active on the fabric.
1. Access the Zone Administration window.
See “
Accessing the Zone Administration Window
” on page 204 for more
information.
2. Select Actions > Disable Zoning to disable the current enabled
Configuration.
The Disable Config warning appears.
3. Click the Yes button if you want to disable the current Configuration.
Saving Changes to an Existing Configuration
To save changes to an existing configuration, perform the following procedure.
1. Access the Zone Administration window.
See “
Accessing the Zone Administration Window
” on page 204 for more
information.
2. Select the Config tab.
3. Make desired changes to Configuration (see “
Creating a Zone
” on page 226).
You can make changes to a Configuration that is currently enabled; changes
will not appear until the Configuration is disabled and re-enabled.
4. Select the Actions > Save Config Only option.
The Configuration changes will be saved. Changes will not take effect until
the Configuration is re-enabled.
To enable the configuration, see “
Enabling a Configuration
” on page 214.
Clearing the Zoning Database
The following procedure disables any active Configuration, and deletes the entire
zoning database.
1. Access the Zone Administration window.
Summary of Contents for StorageWorks 2/32 - SAN Switch
Page 22: ...About this Guide 22 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 44: ...Installation 44 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 186: ...Fabric Watch 186 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 248: ...Zone Administration 248 Web Tools Version 3 1 x 4 1 x User Guide ...
Page 270: ...Troubleshooting Web Tools 270 Web Tools Version 3 1 x 4 1 x User Guide ...