Item
Description
Status
1
UID LED/Button
Solid Blue = Identification is activated
Flashing Blue = System is being managed remotely
Off = Identification is deactivated
2
Power On/Standby
Button/LED
Solid Green = System is on
Flashing Green = Waiting for server power sequence
Solid Amber = System is in standby, but power is still applied
Off = Power cord is not attached, power supply failure has occurred,
no power supplies are installed, facility power is not available or the
power button cable is disconnected
3
Health LED
Solid Green = System health is normal
Flashing Amber = System health is degraded. To identify the
component in a degraded state, see “Systems Insight Display LEDs
(pg 75 in the Server Maintenance and Service Guide)”
Flashing Red = System health is critical. To identify the component
in a critical state, see “Systems Insight Display LEDs (pg 75).” If
possible check iLO/BIOS logs. Also check application’s system log
and SEL log from IPMI interface if possible.
Fast Flashing Red = Power fault (check system and devices)
4
NIC Status LED
Solid Green = Link to network
Flashing Green = Network activity
Off = No network connection
Rear-panel view
Rear-panel view
September 2013
Maintaining and Troubleshooting the HP ProLiant DL360p G8 Server
9