60
HP ProLiant 100 Series Server User Guide
−
For tower-model servers, check the cable connection from the monitor to
the server, and then from the server to the power outlet.
5.
Press any key, or type the password, and wait a few moments for the screen
to activate to be sure the energy saver feature is not in effect.
6.
Be sure the video driver is current. Refer to the third-party video adapter
documentation for driver requirements.
7.
Be sure a video expansion board has not been added to replace onboard
video, making it seem like the video is not working. Disconnect the video
cable from the onboard video, and then reconnect it to the video jack on the
expansion board.
NOTE:
All servers automatically bypass onboard video when a video
expansion board is present.
8.
Press any key, or type the password, and wait a few moments for the screen
to activate to be sure the power-on password feature is not in effect. You can
also tell if the power-on password is enabled if a key symbol is displayed on
the screen when POST completes.
If you do not have access to the password, you must disable the power-on
password by using the Password Disable switch on the system board. Refer
to the server documentation.
9.
If the video expansion board is installed in a PCI Hot Plug slot, be sure the
slot has power by checking the power LED on the slot, if applicable. Refer to
the server documentation.
10.
Be sure the server and the operating system support the video expansion
board.
Monitor does not function properly with energy saver features
Action
: Be sure the monitor supports energy saver features, and if it does not,
disable the features.
Video colors are wrong
Action
:
•
Be sure the 15-pin VGA cable is securely connected to the correct VGA port
on the server and to the monitor.
Summary of Contents for ProLiant DL140
Page 5: ...Contents 5 Customer self repair 98 Acronyms and abbreviations 99 Index 105 ...
Page 6: ......
Page 16: ......
Page 20: ......
Page 31: ...Troubleshooting 31 1 ...
Page 33: ...Troubleshooting 33 2 ...
Page 37: ...Troubleshooting 37 4 ...
Page 39: ...Troubleshooting 39 5 ...
Page 90: ...90 HP ProLiant 100 Series Server User Guide Japanese notice BSMI notice ...
Page 94: ......
Page 104: ......