Troubleshooting
55
3.
Run Insight Diagnostics ("HP Insight Diagnostics" on page
22
) and replace
failed components as indicated.
Memory problems
General memory problems are occurring
Action
:
•
Be sure the memory meets the server requirements and is installed as
required by the server. Some servers may require that memory banks be fully
populated or that all memory within a memory bank must be the same size,
type, and speed. Refer to the server documentation to determine if the
memory is installed properly.
•
Check any server LEDs that correspond to memory slots.
•
If you are unsure which DIMM has failed, test each bank of DIMMs by
removing all other DIMMs. Then, isolate the failed DIMM by switching
each DIMM in a bank with a known working DIMM.
•
Remove any third-party memory.
•
Run Insight Diagnostics to test the memory.
Server is out of memory
Action
:
1.
Be sure the memory is configured properly. Refer to the application
documentation to determine the memory configuration requirements.
2.
Be sure no operating system errors are indicated.
3.
Be sure a memory count error ("Memory count error exists" on page
55
) did
not occur. Refer to the message displaying memory count during POST.
Memory count error exists
Possible Cause
: The memory modules are not installed correctly.
Action
:
1.
Be sure the memory modules are supported by the server. Refer to the server
documentation.
Summary of Contents for ProLiant DL140
Page 5: ...Contents 5 Customer self repair 98 Acronyms and abbreviations 99 Index 105 ...
Page 6: ......
Page 16: ......
Page 20: ......
Page 31: ...Troubleshooting 31 1 ...
Page 33: ...Troubleshooting 33 2 ...
Page 37: ...Troubleshooting 37 4 ...
Page 39: ...Troubleshooting 39 5 ...
Page 90: ...90 HP ProLiant 100 Series Server User Guide Japanese notice BSMI notice ...
Page 94: ......
Page 104: ......