Chapter 6
Replacing Parts
89
Retaining Latches
DIMM Slot
Keys
Notches
DIMM to Slot Alignment
e. Holding the DIMM at 90 degrees to the system board, press the DIMM fully into the slot until
the retaining latches close.
f. If the latches do not close, the DIMM is not inserted correctly.
2. Repeat all of Step 1, to install the additional DIMMs for your memory configuration.
3. Replace the air duct and latch it into the chassis.
4. Replace the cover.
5. Fasten the six thumbscrews securing the cover to the chassis.
6. Replace the external cables and power cord.
7. Power up the NetServer as described in Chapter 1.
NOTE
Most DIMMs are dimensionally identical, so, if you have two or more DIMMs
installed, you may verify all DIMMs are seated by sliding a straight edge (a pen, for
example) across the top edges and verify it remains in continuous contact with all of
the DIMMs.
8. If the DIMMs are not seated properly you may get a blank screen.
Accessory Boards
Removing Accessory Boards
To remove an accessory board, refer to the following procedure
1. If the NetServer is operating, power down the NetServer.
2. Disconnect the power cord and any external cables connected to the NetServer. If necessary,
label each one to expedite re-assembly.
3. Remove the cover and turn in the NetServer feet (so that the NetServer will lie flat on its side).
WARNING
The power supply will continue to provide standby current to the NetServer E 800
until the power cord is disconnected.
Summary of Contents for NetServer e 800
Page 1: ...HP NetServer E 800 Service Manual Online Version 1 0 Last Updated May 2000 ...
Page 27: ...21 3 Parts Information Exploded View Cover and Bezel 1 2 3 4 ...
Page 28: ...Chapter 3 Parts Information 22 Exploded View Drives Shelf Mount 5 6 7 8 9 ...
Page 29: ...Chapter 3 Parts Information 23 Exploded View Power Supply and Drives Cage Mount 10 13 11 12 ...
Page 30: ...Chapter 3 Parts Information 24 Exploded View Exhaust Fan and System Board 14 15 ...
Page 100: ...Chapter 6 Replacing Parts 94 ...