Chapter 6
Replacing Parts
71
Replacing a Hard Disk Drive (DAT shown)
Hard Disk Drive (Cage Mounted)
Removing a Hard Disk Drive (Cage Mounted)
The replacement of the mass storage cage mounted drives is the same for IDE or SCSI drives. The IDE
drives require the setting of jumpers on the drives for the master and slave configuration before installing the
drives. The SCSI drives are set up during the operation of the SCSI configuration utility.
CAUTION
Install and remove connectors carefully, and avoid displacing any pins.
1. If the NetServer is operating, power down the NetServer.
2. Disconnect the power cord and any external cables connected to the NetServer. If necessary,
label each one to expedite re-assembly.
3. Remove the cover and turn in the NetServer feet (so that the NetServer will lie flat on its side).
4. Lay the NetServer on its side (components showing).
5. Unsnap the air duct and move it out of the way.
Summary of Contents for NetServer e 800
Page 1: ...HP NetServer E 800 Service Manual Online Version 1 0 Last Updated May 2000 ...
Page 27: ...21 3 Parts Information Exploded View Cover and Bezel 1 2 3 4 ...
Page 28: ...Chapter 3 Parts Information 22 Exploded View Drives Shelf Mount 5 6 7 8 9 ...
Page 29: ...Chapter 3 Parts Information 23 Exploded View Power Supply and Drives Cage Mount 10 13 11 12 ...
Page 30: ...Chapter 3 Parts Information 24 Exploded View Exhaust Fan and System Board 14 15 ...
Page 100: ...Chapter 6 Replacing Parts 94 ...