Chapter 6
Replacing Parts
84
Replacing the Processor
1. Ensure the processor speed of the second processor (CPU 2) is the same as the existing
processor before installing the second processor.
NOTE
If you are upgrading the second processor to a faster processor speed than the
primary processor, the primary processor must also be changed. Both processors
must have the same product number, which includes the same clock speed, cache
size, and FSB speed.
The supported processors only perform at the rated speed indicated on the
processor in the HP NetServer.
2. Open the ZIF (Zero Insertion Force) lever to allow removal of the terminator installed in the
processor socket.
You need to pull the lever out away from the ZIF socket and then raise it to a full 90
°
to the
system board.
ZIF
Lever
Processor Socket
Terminator
NOTE
Retain the terminator for future use. The NetServer will not operate properly if using
only one processor with no terminator installed.
3. Lift the terminator out of the socket and place it on anti-static surface or container.
4. Align the second processor over the empty processor socket.
Summary of Contents for NetServer e 800
Page 1: ...HP NetServer E 800 Service Manual Online Version 1 0 Last Updated May 2000 ...
Page 27: ...21 3 Parts Information Exploded View Cover and Bezel 1 2 3 4 ...
Page 28: ...Chapter 3 Parts Information 22 Exploded View Drives Shelf Mount 5 6 7 8 9 ...
Page 29: ...Chapter 3 Parts Information 23 Exploded View Power Supply and Drives Cage Mount 10 13 11 12 ...
Page 30: ...Chapter 3 Parts Information 24 Exploded View Exhaust Fan and System Board 14 15 ...
Page 100: ...Chapter 6 Replacing Parts 94 ...